Current Location:Home ›› Products ›› Levelgauge ›› Split ultrasonic level gauge

Split ultrasonic level gauge

Function: Split

Protection level: IP65 for display instrument, IP68 for probe

Probe installation: according to range and probe selection

product details

一、Packaging & Delivery

Selling Units:  Single item

Single package size: : 39*26.5*16.5cm

Single gross weight:2.5 KG

Quantity(Units)

1 - 50

>50

Est. Time(days)

15

To be negotiated


Lead Time:

二、The interface of ultrasonic level meter under operating mode is as follows:

 

  说明: 液位计英文菜单主界面

 

       English Display Interface

(1)After power-on display of the meter, long press the set button (SET) for 2s to enter in the main menu.

The menu modes include expert setting mode and simply setting mode.

The menu query table of simple setting mode is as shown in the table below.

         

163780535077082.gif

 

(2)Select measuring mode:

Measuring modes are divided into distance measuring mode and material level measuring mode. And the factory default is material level measurement.

(3)Input probe height value to “reference zero point” (probe height is the distance from probe emitting surface to tank bottom or pool bottom).

  ① Under distance measuring mode, setting of reference zero point is meaningless and the positions of maximum of measuring range and minimum of measuring range are as shown in Fig. 1.1.

② Under material level measuring mode, the positions of reference zero point, maximum of measuring range and minimum of measuring range are as shown in Fig. 1.2.

 

163780535014635.gif       

Fig. 1.1 Diagram of Distance                        Fig. 1.2 Diagram of Material

Measurement                                                        Level Measurement


Minimum of measuring range: it is the value of distance between the reference plane to the position, which is positive when the minimum of measuring range is above the reference plane and negative when the minimum of measuring range is below the reference plane. The output current is 4mA when the liquid level is at such position.

Maximum of measuring range: it is the value of distance between the reference plane to the position, which is positive when the maximum of measuring range is above the reference plane and negative when the maximum of measuring range is below the reference plane. The output current is 20mA when the liquid level is at such position.

(6)The installed equipment must be grounded truthfully and independently and shall not share the public grounding with electrical cabinet or meter box.

 

(7)The signal line shall not be wired in the same trunking with the power line and it shall be installed independently through metal tube or far away from the power line. If the signal line is not installed through tube independently, it shall be kept at least 1m away from the power line.

III. Main Technical Indicators

Measuring range

5m, 10m, 15m, 20m, 30m, 40m, 50m,   60m, 70m

Measurement accuracy

0.5%

Resolution ratio

3mm or 0.1% (whichever is greater)

Display

Chinese LCD

Analog output

4~20mA/ 510Ω load

Relay output

2 groups for single channel and 4 groups for double channels (optional)   AC 250V/ 8A or DC 30V/ 5A, state programmable

Power supply

Standard configuration: 220V AC+15%  50Hz

Optional: 24VDC 120mA

Customized: 12VDC or battery powered

Ambient temperature

Display instrument: -20~+60ºC

Probe: -20~+80ºC

Communication

485, 232 communication (optional) (manufacturer agreement)

IP grade

Display instrument: IP65, probe: IP68

Probe cable

100m available, standard configuration: 10m

Probe installation

Select type based on measuring range and probe


Product power   consumption

The power supply of separate type is 24V power and the   electricity consumed for such type is 100mA without relay, 120mA with a   replay, 145mA with 2 relays, 170mA with 3 relays and 190mA with 4 relays.

Specific power consumed is shown in below:

24×100mA=2.4W for   separate type without relay;

24×120mA=2.9W for   separate type with a relay;

24×145mA=3.5W for   separate type with 2 relays;

24×170mA=4.1W for   separate type with 3 relays;

24×190mA=4.6W for   separate type with 4 relays;

 

 IV.Installation dimension of level meter :

Standard separate-type ultrasonic level meter:

 

image007.jpg                163780535070272.jpg

Object Picture                                                              Structural Drawing

        163780535099071.jpg                       163780535075564.jpg

                                                                  

 Thread M48×2 or G2 Sensor                             Thread M60×2 or G2  Sensor

 

     163780535172293.jpg     

      Thread M78×2 Sensor                  

 

4.2 Installation Guide

4.2.1 Understand terminology

①Measuring range: the meaning of measuring range is very important for meter type selection. Please refer to the diagrams below.

 

163780535121422.gif

V. Field cases:

04.jpg

Product application:

 Mainly used in sewage plant, water plant, mine, water conservancy, power plant, chemical plant, steel plant

The monitoring of waterlogging and water, sewage quality, urban pipeline and rainfall station in the construction of smart city project; applicable to the monitoring of rainfall point of existing water conservancy projects, river water and rain monitoring, reservoir water and rain monitoring, flow station, irrigation area, open channel monitoring, etc.; automatic monitoring of water plant, on-line water quality monitoring and secondary water supply monitoring of smart water project; suitable for intelligent water project It is used for the monitoring of collapse and landslide points, debris flow and surface water level of geological disaster projects

VI. Manufacturer:

05.jpg

TOP